Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1211887.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,864.00
Current Penalty: $10,864.00
Issuance Date: 03/07/2017
Nr Instances: 1
Nr Exposed: 12
Abatement Date: 03/31/2017
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 03/31/2017
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 03/07/2017 | $10,864.00 | 03/31/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Jack Shop: On or about February 21, 2017 lathe operators were permitted to lift the chuck guard and then secure and/or remove work pieces into and out of the chuck on the MAZAK lathes without utilizing the procedures for de-energizing the equipment. This exposed the lathe operators to being struck by heavy metal work pieces and being pulled into rotating parts if the lathe's spindle was accidentally started.
Translate