Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1209903.015
Citation: 01001
Citation Type: Serious
Abatement Date: 05/14/2017 2
Initial Penalty: $6,338.00
Current Penalty: $2,535.20
Issuance Date: 02/28/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 03/24/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/24/2017 | $2,535.20 | 05/14/2017 | Serious | |
Penalty | Z: Issued | 02/28/2017 | $6,338.00 | 04/14/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section: At 3883 Delor Street, St. Louis, MO 63116, specifically Building No. 2, Work Center #1902, the employer did not ensure that a specific procedure was developed, documented, or utilized for the Bystronic Press Brake, m/n Beyeler PR320 1 PC. Authorized employee(s) were exposed to a serious caught-in hazard. This violation was observed on 02/21/17.