Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1204987.015
Citation: 01001
Citation Type: Serious
Abatement Date: 07/28/2017 2
Initial Penalty: $12,675.00
Current Penalty: $7,500.00
Issuance Date: 03/14/2017
Nr Instances: 1
Nr Exposed: 40
Related Event Code (REC): A
Gravity: 10
Report ID: 0524700
Contest Date: 04/07/2017
Final Order: 09/11/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/11/2017 | $7,500.00 | 07/28/2017 | Serious | |
Penalty | C: Contested | 04/10/2017 | $12,675.00 | 03/21/2017 | Serious | |
Penalty | Z: Issued | 03/14/2017 | $12,675.00 | 03/21/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: a. Crown Equipment Corp. - Celina, Ohio: On or about January 17, 2017, the employer did not ensure the point of operation on Cincinnati press brake No. 040216 (s/n 52916) was adequately guarded to protect employees from crushing and amputation hazards.