Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1193643.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $9,799.00
Current Penalty: $7,529.00
Issuance Date: 12/15/2016
Nr Instances: 4
Nr Exposed: 100
Abatement Date: 02/03/2017
Gravity:
Report ID: 0729300
Contest Date:
Final Order: 01/09/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/09/2017 | $7,529.00 | 02/03/2017 | Other | |
| Penalty | Z: Issued | 12/15/2016 | $9,799.00 | 02/03/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Inside of the Commercial Press Department, specific lockout/tagout procedures were not developed in writing for the following machines: a/ Mueller-Martini Web Press, m/n Concept NT, s/n MA581873. b/ Komori Web Press, m/n L584OP, s/n 108. c/ Heidelberg Web Press, m/n SM-102-8-PSL. d/ Heidelberg Web Press, m/n SM-74-8-PSL, s/n 625198.
Translate