Violation Detail
Standard Cited: 19100024 H Step bolts and manhole steps.
Inspection Nr: 1176576.015
Citation: 01001
Citation Type: Serious
Abatement Date: 04/14/2017 2
Initial Penalty: $3,802.00
Current Penalty: $2,281.00
Issuance Date: 03/01/2017
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC):
Gravity: 1
Report ID: 0213900
Contest Date:
Final Order: 03/16/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/16/2017 | $2,281.00 | 04/14/2017 | Serious | |
Penalty | Z: Issued | 03/01/2017 | $3,802.00 | 03/27/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: a) Facility, Shop: The stairs leading to the overhead storage area were not provided with a mid-rail, on or about 9/12/2016. b) Facility, Shop: The stairs leading to the file room were not provided with a standard stair rail system, on or about 9/12/2016. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.