Violation Detail
Standard Cited: 19260150 C01 VI Fire protection.
Inspection Nr: 1172732.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $3,135.00
Current Penalty: $3,135.00
Issuance Date: 09/29/2016
Nr Instances: 1
Nr Exposed: 10
Abatement Date:
Gravity: 5
Report ID: 0317900
Contest Date: 10/31/2016
Final Order: 01/17/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/17/2017 | $3,135.00 | Serious | ||
Penalty | C: Contested | 11/08/2016 | $3,135.00 | Serious | ||
Penalty | Z: Issued | 09/29/2016 | $3,135.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite. a) 2101 - 2104 Jefferson on the Creek, Warminster, PA, Worksite, - On or about August 25, 2016, the employer was storing approximately eight gallons of gasoline to refuel air compressors, but a fire extinguisher of the appropriate rating was not available within 50 feet of this location.