Violation Detail
Standard Cited: 19100147 C07 III B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1168212.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $9,603.00
Current Penalty: $0.00
Issuance Date: 11/10/2016
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 12/01/2016
Gravity:
Report ID: 0626000
Contest Date:
Final Order: 11/29/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/29/2016 | $0.00 | 12/01/2016 | Other | |
Penalty | Z: Issued | 11/10/2016 | $9,603.00 | 12/01/2016 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed or whenever the employer believed that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: On or about August 8, 2016, and at times prior thereto, at this manufacturing plastic plant production area, a machine operator corrected a wrinkle with plastic material on a roller of the slitter machine/precut station and deviated from the company written procedure. The employer did not retrain the operators in the correct energy control procedure.