Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1168054.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,471.00
Current Penalty: $7,971.00
Issuance Date: 09/19/2016
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 10/06/2016
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 10/07/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/07/2016 | $7,971.00 | 10/06/2016 | Serious | |
Penalty | Z: Issued | 09/19/2016 | $12,471.00 | 10/06/2016 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: At the Digital Room, the employer did not develop specific hazardous energy control procedure for electrical and pneumatic when performing maintenance on the Spartanics, Dye Cutter 2, Model M500-140, serial number 11088, exposing employees to struck by hazards.