Violation Detail
Standard Cited: 19260651 J02 Specific Excavation Requirements.
Inspection Nr: 1164417.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,741.00
Current Penalty: $2,805.75
Issuance Date: 12/13/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/19/2016
Gravity: 10
Report ID: 0317000
Contest Date:
Final Order: 02/01/2017
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/01/2017 | $2,805.75 | 12/19/2016 | Serious | |
| Penalty | Z: Issued | 12/13/2016 | $3,741.00 | 12/19/2016 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) Jobsite - The employer did not ensure that the spoil pile was kept a minimum of 2 feet from the edge of the excavation exposing employees to struck-by hazards. Observed on or about 06 JULY 2016.