Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1146516.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,451.00
Current Penalty: $2,900.00
Issuance Date: 10/18/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/28/2016
Gravity: 5
Report ID: 0419400
Contest Date:
Final Order: 11/07/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/07/2016 | $2,900.00 | 10/28/2016 | Serious | |
| Penalty | Z: Issued | 10/18/2016 | $5,451.00 | 10/28/2016 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) Boiler Room, Southwest Side - On or about May 12, 2016 a rotating shaft located at the motor on the backside of the under air fire fan lacked a guard exposing an employee to he hazard of being entangled in the rotating shaft.