Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1141246.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $7,000.00
Current Penalty: $5,250.00
Issuance Date: 05/05/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0316700
Contest Date:
Final Order: 06/01/2016
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/01/2016 | $5,250.00 | Serious | ||
| Penalty | Z: Issued | 05/05/2016 | $7,000.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: (a) Dart Container Corporation (D) Line Bagger - The employer did not effectively guard the point of operation on the D line baggers machine head that heats and perforates the plastic film bagger where employees place heat tape, thereby exposing employees to injuries, on or about April 19, 2016. No abatement certification or documentation required.