Violation Detail
Standard Cited: 19100023 C01 Ladders.
Inspection Nr: 1129920.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,000.00
Current Penalty: $3,600.00
Issuance Date: 06/10/2016
Nr Instances: 2
Nr Exposed: 5
Abatement Date: 07/07/2016
Gravity: 5
Report ID: 0830100
Contest Date:
Final Order: 07/01/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/01/2016 | $3,600.00 | 07/07/2016 | Serious | |
Penalty | Z: Issued | 06/10/2016 | $6,000.00 | 07/07/2016 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: (a) Easy Rider: On or about February 29, 2016 and at times prior, employees were exposed to fall hazards of approximately 11 feet while using an unguarded elevated service platform to access and egress the lift's control room. (b) Base Lodge: On or about February 29, 2016 and at times prior, employees were exposed to fall hazards of approximately 11 feet while using an unguarded elevated service platform to access and egress the lift's control room.