Violation Detail
Standard Cited: 19100107 C06 Spray finishing using flammable and combustible materials.
Inspection Nr: 1113549.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,930.00
Current Penalty: $5,544.00
Issuance Date: 03/03/2016
Nr Instances: 1
Nr Exposed: 88
Abatement Date: 09/09/2016
Gravity: 10
Report ID: 0111100
Contest Date:
Final Order: 03/07/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/07/2016 | $5,544.00 | 09/09/2016 | Serious | |
Penalty | Z: Issued | 03/03/2016 | $6,930.00 | 03/09/2016 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.107(c)(6): Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spray area, and not separated therefrom by partitions, produced sparks under normal operating conditions and did not otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations: Paint Area, West Wall - Wall mounted electrical outlets, a circuit breaker panel, light switches, junction boxes, and electrical wiring, as close as 6.9 feet from the flammable and combustible liquids spray area, produced sparks under normal operating conditions and did not conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.