Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1111924.015
Citation: 01001
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $70,000.00
Current Penalty: $49,000.00
Issuance Date: 06/01/2016
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 11/22/2016
Gravity: 10
Report ID: 0523900
Contest Date: 06/01/2016
Final Order: 07/25/2016
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 07/25/2016 | $49,000.00 | 11/22/2016 | Repeat | |
Penalty | Z: Issued | 06/01/2016 | $70,000.00 | 06/29/2016 | Repeat | |
Penalty | C: Contested | 06/01/2016 | $70,000.00 | 06/29/2016 | Repeat |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Machine number UC450, VersaClipper clip rail machine; On or before December 8, 2015, energy isolation devices were not located and operated in a manner to isolate energy sources while the machine operators performed servicing tasks including but not limited to clearing jammed materials and changing the location of chain dogs on the material feed chain.