Violation Detail
Standard Cited: 19100023 A02 Ladders.
Inspection Nr: 1110870.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $5,500.00
Current Penalty: $3,850.00
Issuance Date: 05/02/2016
Nr Instances: 5
Nr Exposed: 2
Abatement Date: 05/24/2016
Gravity:
Report ID: 0729700
Contest Date:
Final Order: 05/24/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/24/2016 | $3,850.00 | 05/24/2016 | Other | |
| Penalty | Z: Issued | 05/02/2016 | $5,500.00 | 05/24/2016 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening: Employees engaged in grain handling activities were exposed to fall hazards in that ladderway openings were not guarded in the following locations: a) The top platform of the South bin (24 foot fall hazard) b) The top platform of the West bin (18 foot fall hazard) c) The top platform of the North bin (18 foot fall hazard) d) The top platform of the West flat storage (20 foot fall hazard) e) The top platform of the East flat storage (11 foot fall hazard)