Standard Cited: 19260451 B01 General requirements.

Inspection Nr: 1100744.015

Citation: 01001

Citation Type: Serious

Abatement Status: Corrected During Inspection

Initial Penalty: $6,300.00

Current Penalty: $3,500.00

Issuance Date: 03/30/2016

Nr Instances: 1

Nr Exposed: 6

Abatement Date:

Gravity: 10

Report ID: 0111500

Contest Date: 04/25/2016

Final Order: 11/04/2016

Related Event Code (REC): A

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty F: Formal Settlement 11/04/2016 $3,500.00   Serious  
Penalty F: Formal Settlement 11/04/2016 $0.00   Serious  
Penalty C: Contested 04/25/2016 $0.00   Serious  
Penalty C: Contested 04/25/2016 $6,300.00   Serious  
Penalty Z: Issued 03/30/2016 $0.00   Serious  
Penalty Z: Issued 03/30/2016 $6,300.00   Serious  

Text For Citation: 01 Item/Group: 001 Hazard:

29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii). Location: West Chimney, Yale University Power Plant, 120 Tower Parkway, New Haven, CT 06511 Instance "A": The approximately 7 foot 5 inch diameter platform inside the chimney at the breech are of the chimney was equipped with one 1 1/2 inch thick, 9 5/8 inch wide and 7 foot 1/2 inch long wood scaffold plank and one 1 3/4 inch thick, 9 1/2 inch wide, and 7 foot long wood scaffold plank and therefore was not fully planked. 29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping or have guardrails which block employee access to the cantilevered end. Location: West Chimney, Yale University Power Plant, 120 Tower Parkway, New Haven, CT 06511 Instance "B": The two wood scaffold planks measuring 1 1/2 inches thick, 9 5/8 inches wide and 7 feet 1/4 inch long and 1 3/4 inches thick, 9 1/2 inches wide and 7 feet long were not installed in order to allow the cantilevered portion of the planks to sufficiently support employees and/or materials without tipping.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.