Standard Cited: 19260757 A04 Open web steel joists.
Inspection Nr: 1090285.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,850.00
Current Penalty: $3,410.00
Issuance Date: 03/02/2016
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 04/10/2017
Gravity: 5
Report ID: 0111400
Contest Date: 03/28/2016
Final Order: 05/05/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/05/2017 | $3,410.00 | 04/10/2017 | Serious | |
| Penalty | C: Contested | 03/31/2016 | $3,850.00 | 03/10/2016 | Serious | |
| Penalty | Z: Issued | 03/02/2016 | $3,850.00 | 03/10/2016 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.757(a)(4): Where steel joists at or near columns span more than 60 feet (18.3 m), the joists were not set in tandem with all bridging installed and an alternative method of erection, which provides equivalent stability to the steel joist, was not designed by a qualified person and was not included in the site-specific erection plan. Jobsite: Bays between column lines 4 and 5. Steel joists at or near columns were not hoisted in tandem and were set 'one at a time'. The site specific steel erection plan makes no provision for the alternate erection of steel joists longer than 60 feet.