Violation Detail
Standard Cited: 19260703 A02 Requirements for cast-in-place Concrete.
Inspection Nr: 1090038.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/02/2016
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 03/29/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 03/02/2016 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.703(a)(2): 29CFR1926.703(a)(2): Drawings or plans including all revisions for jack layout, formwork, (including shoring equipment), working decks and scaffolds were not available at the jobsite. (a) Construction Site - On or about September 8, 2015 approved engineered drawings were not available at the jobsite for the structural design changes from an elevated wood floor to a concrete floor. The changes were not submitted to the designer and engineer to develop new drawings for the changes.