Violation Detail
Standard Cited: 19260451 A01 General requirements.
Inspection Nr: 1087369.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 02/25/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/01/2016
Gravity: 10
Report ID: 0215000
Contest Date: 03/16/2016
Final Order: 09/30/2016
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 09/30/2016 | $7,000.00 | 03/01/2016 | Serious | |
| Penalty | C: Contested | 03/21/2016 | $7,000.00 | 03/01/2016 | Serious | |
| Penalty | Z: Issued | 02/25/2016 | $7,000.00 | 03/01/2016 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(a)(1): Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it: a) 2nd floor southwest elevator shaft: On or about August 25, 2015 A component of the scaffold platform previously in place when erected in the elevator shaft had been removed and the platform partially collapsed.