Violation Detail
Standard Cited: 19100147 C04 II C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1064499.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,000.00
Current Penalty: $3,000.00
Issuance Date: 07/31/2015
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/26/2015
Gravity: 5
Report ID: 0627510
Contest Date:
Final Order: 08/17/2015
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/17/2015 | $3,000.00 | 08/26/2015 | Serious | |
| Penalty | Z: Issued | 07/31/2015 | $5,000.00 | 08/26/2015 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. On or about May 19, 2015, in the meat grinding room, employees engaged in cleaning the patty machine, used a lock-out/tag-out procedure that did not specify who the authorized or affected employees were, were exposed to caught-between/struck-by hazards.
Translate