Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1063002.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,300.00
Current Penalty: $6,300.00
Issuance Date: 06/08/2015
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/25/2015
Gravity: 10
Report ID: 0317500
Contest Date:
Final Order: 07/02/2015
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 06/08/2015 | $6,300.00 | 06/25/2015 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Facility- 400 Technology Drive, Coal Center, PA: On or about May 12, 2015, employees were not required to de-energize and isolate the ZES breaker which ultimately exposed the workers to the operation or the rubber roll and antilock roll when the Wade Die Cutter was opened. OR IN THE ALTERNATIVE: 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Facility- 400 Technology Drive, Coal Center, PA: On or about May 12, 2015, employees were exposed to ingoing nip points from the antilock roll and the rubber roll due to lack of guarding.
Translate