Violation Detail
Standard Cited: 19260651 F Specific Excavation Requirements.
Inspection Nr: 1062492.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,800.00
Current Penalty: $2,800.00
Issuance Date: 05/21/2015
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0215000
Contest Date:
Final Order: 06/17/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 05/21/2015 | $2,800.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.651(f): A warning system such as barricades, hand or mechanical signals, or stop logs was not utilized when mobile equipment was operated adjacent to an excavation, when such equipment was required to approach the edge of an excavation, and the operator does not have a clear and direct view of the edge of the excavation, a warning system shall be utilized. LOCATION; 579 Van Buren Street, North West corner of project. On or About January 15, 2014 a)Employee was operating a Bobcat type front end loader and was moving dirt to backfill against the exposed foundation. There was warning system or stop log being used and the bobcat fell into the excavation.