Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1037687.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 07/31/2015
Nr Instances: 5
Nr Exposed: 5
Abatement Date: 10/02/2015
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 08/25/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/25/2015 | $7,000.00 | 10/02/2015 | Serious | |
Penalty | Z: Issued | 07/31/2015 | $7,000.00 | 08/28/2015 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Welding area; Energy isolation procedures were not utilized when the machine operators and setup personnel performed cleaning and servicing tasks on welders such as, but not limited to: (i) The Fanic Robotic Welder #PL301, (ii) The OTC Welding Robot #PL302, (iii) The ArcWorld by Motoman 100 welding robot #PL303, (iv) The High Weld spot welder #PL350, and (v) The T.J. Snow spot welder #PL351.