Violation Detail
Standard Cited: 5A0001 OSH Act General Duty Paragraph
Inspection Nr: 103367546
Citation: 01001
Citation Type: Serious
Abatement Status: X
Initial Penalty: $1,500.00
Current Penalty: $685.00
Issuance Date: 05/30/1991
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/11/1991
Gravity: 10
Report ID: 0636900
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/17/1991 | $685.00 | 06/11/1991 | Serious | |
| Penalty | Z: Issued | 05/30/1991 | $1,500.00 | 06/11/1991 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard: EXPLOSION
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Employee(s) exposed to fire hazard while working in rod basket on the Wilson Mogul 42 service rig, S/N 10483, on or about March 1, 1991. Among other methods, one feasible and acceptable abatement to correct this hazard would be installation of a properly rigged and secured emergency descent device or other satisfactory auxiliary means of egress such as specified in section 4.7, paragraph 4.7.1 of A.P.I. RP 54, First Edition, January, 1981, page 11. Essential elements of this procedure would include: 1) Staking out a securely anchored one-half (1/2) inch wire rope escape line attached to the derrick, mast or pole so as to provide a ready convenient means of escape from the derrickman's working platform or rod basket. 2) The escape line route is to be kept clear of obstructions. 3) A safety device is to be provided to permit fast and emergency exit from the derrickman's working platform to a safe place. 4) The tension on the escape line is to be periodically checked and adjusted to assure a safe landing and to allow the derrickman to stop twenty (20) feet from the anchor point. 5) The ground anchor point of the escape line is to be located a minimum lateral distance from the derrick, mast or pole equal to the height above ground to the point where the escape line is fastened to the derrick, mast or pole.
Translate