Violation Detail
Standard Cited: 5A0001 OSH Act General Duty Paragraph
Inspection Nr: 102355740
Citation: 01001
Citation Type: Serious
Abatement Status: X
Initial Penalty: $720.00
Current Penalty: $365.00
Issuance Date: 03/14/1990
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 03/17/1990
Gravity: 09
Report ID: 0523400
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/03/1990 | $365.00 | 03/17/1990 | Serious | |
Penalty | Z: Issued | 03/14/1990 | $720.00 | 03/17/1990 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard: CRUSHING
Section 5 (a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) On February 5, 1990 employees(s) were exposed to a potential fall and/or crushing hazard which was caused by inadequate bracing and support of roof trusses. A feasible method of abatement includes but is not limited to: adequate bracing of continuous lumber (no less than 2" x 4" nominal) running parallel to the ridge line and spaced 8' to 10' apart in the top chord and bottom chord planes. These are to be supplemented with diagonal bracing (no less than 2" x 4" nominal) spaced no more than 20 feet apart in the top and bottom chord planes and among the web members. These are to be sucured with 16D nails.