Violation Detail
Standard Cited: 19260350 J Gas welding and cutting.
Inspection Nr: 1021352.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $1,600.00
Current Penalty: $1,120.00
Issuance Date: 02/18/2015
Nr Instances: 1
Nr Exposed: 20
Abatement Date: 03/16/2015
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 03/03/2015
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/03/2015 | $1,120.00 | 03/16/2015 | Serious | |
| Penalty | Z: Issued | 02/18/2015 | $1,600.00 | 03/16/2015 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.350(j): Additional rules. For additional details not covered in this subpart, applicable technical portions of American National Standards Institute, Z49.1-1967, Safety in Welding and Cutting, shall apply. a.) Heeter Construction, Inc., Bluestone Dam: On or about 1/26/15, the employer did not follow section 3.5.3.2c of ANSI Z49.1-1967, in that flash-back protection was not provided for employees using the gas burning torches. ABATEMENT CERTIFICATION IS REQUIRED