Violation Detail
Standard Cited: 5A0001 OSH Act General Duty Paragraph
Inspection Nr: 1019218.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,930.00
Current Penalty: $4,851.00
Issuance Date: 03/26/2015
Nr Instances: 15
Nr Exposed: 95
Abatement Date: 09/15/2015
Gravity: 10
Report ID: 0830600
Contest Date: 04/17/2015
Final Order: 09/21/2015
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 09/21/2015 | $4,851.00 | 09/15/2015 | Serious | |
| Penalty | C: Contested | 04/17/2015 | $6,930.00 | 04/21/2015 | Serious | |
| Penalty | Z: Issued | 03/26/2015 | $6,930.00 | 04/21/2015 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees including burns, shocks, and electrocution: (a) On or about January 15, 2015, and at times prior, employees who worked in both dry and wet and damp locations were exposed to electrical hazards in that there were missing knockout plugs in receptacles, open junction boxes, strain on wiring components, missing switch covers, and spliced electrical wiring in the following locations throughout the plant: 1) In the package assembly room, strain on the electrical cord for lift truck model W40Z, 110V. 2) In the back wall of the metal detector room, wall receptacle missing knockout plug, 110V. 3) In the metal detector room, pendant receptacle missing knockout plug, 110V. 4) In the product cooler room next to the loading dock, open junction box, no cover, 110V. 5) In the product cooler managers office, open receptacle, no cover, 110V. 6) Outside of grow room #4, open receptacle, wet location, 480V. 7) Outside of grow room # 16, strain on cord at bottom of panel, wet location. 8) Outside of grow room #16, strain on cord for water pump #6 where the cord enters the motor, Dayton model 1D878, 240V, wet location. 9) Outside of grow room # 11, missing switch cover, wet location, 110V. 10) Outside of grow room #9, missing switch cover, wet location, 110V. 11) Outside casing grow room # 2, strain where cord enters the plug of humidifier pump, wet location, 110V. 12) Outside of spawn room # 3, missing switch cover, wet location, 110V. 13) In the tunnels area, spliced winch puller cable, cable connects to Appleton AR 20044 480V receptacle. 14) In the tunnels area east wall, open junction box, no cover, wet location, 110V. 15) In the tunnels area main power room, missing knockout plug on switch box, 110V. Colorado Mushroom Farm, LLC. formerly known as Rakhra Mushroom Farm Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 588999, citation number 1, item number 1 and was affirmed as a final order on January 4, 2013 ,with respect to a workplace located at 10719 Road 5 South, Alamosa, CO 81101. Colorado Mushroom Farm, LLC. formerly known as Rakhra Mushroom Farm Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 110230, citation number 1, item number 1 and was affirmed as a final order on April 17, 2012, with respect to a workplace located at 10719 Road 5 South, Alamosa, CO 81101. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").