Violation Detail
Standard Cited: 19100119 D03 I B Process safety management of highly hazardous chemicals.
Inspection Nr: 1008319.015
Citation: 01001
Citation Type: Serious
Abatement Date: 06/18/2015 5
Initial Penalty: $7,000.00
Current Penalty: $12,675.00
Issuance Date: 05/14/2015
Nr Instances: 5
Nr Exposed: 24
Related Event Code (REC): A
Gravity: 10
Report ID: 0626700
Contest Date: 06/23/2015
Final Order: 06/08/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/08/2017 | $12,675.00 | 06/18/2015 | Serious | |
Penalty | C: Contested | 06/23/2015 | $7,000.00 | 06/18/2015 | Serious | |
Penalty | Z: Issued | 05/14/2015 | $7,000.00 | 06/18/2015 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.119(d)(3)(i)(B): [Process safety] information pertaining to the equipment in the process did not include the piping and instrument diagrams (P&IDs): On November 15, 2015 and at times prior thereto, piping and instrument diagrams, such as the following, were inaccurate or incomplete a) Piping and Instrument Diagram (P&ID) W1173976, line 11965 reflects that it vents to the MIC Incinerator instead of the NRS. b) Piping and Instrument Diagram (P&ID) W363888, line 2822 reflects G82K with a bull plug, but it has been modified. c) Piping and Instrument Diagram (P&ID) W363888, line 2817 refelects G32K with a blind flange, but it has been modified. d) Piping and Instrument Diagram (P&ID) W1722137, did not reflect the piping modification for the Change of Design (TCOD 2011-21) when piping was modified to route a drain line from the AAO vent header to the MIC Caustic Scrubber. Abatement documentation required for this item. Agreed Penalty: $ 12,675