Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1005521.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,500.00
Current Penalty: $2,700.00
Issuance Date: 01/27/2015
Nr Instances: 5
Nr Exposed: 6
Abatement Date: 03/02/2015
Gravity: 5
Report ID: 0627500
Contest Date:
Final Order: 02/12/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/12/2015 | $2,700.00 | 03/02/2015 | Serious | |
Penalty | Z: Issued | 01/27/2015 | $4,500.00 | 01/29/2015 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about October 31, 2014, and at times prior thereto, the employers lockout-tagout procedures did not specifically outline the rules and techniques to be utilized for the control of all hazardous energy associated with the following equipment: a) NISSEI No. 55 Model FN 2000, Serial No. S11S299 b) NISSEI No. 56 Model FN 3000, Serial No. S14S254 c) ENGEL No. 39 Model ES330H/85VRB, No. Serial 7179-085-96 d) TOSHIBA No. 51 Model EC180-6A, No. Serial 006705 e) MILACRON/FANUC ROBOSHOT No. 61- Model S-2000i110B, No. Serial A8500AA006705