Powered by GoogleTranslate

Inspection Detail

Inspection: 3170255 - Luis Raul Sierra

Inspection Information - Office: Pr-E-San Juan 0257260

 

Inspection Nr: 3170255
Report ID: 0257260
Date Opened: 03/07/1986

Site Address:
Luis Raul Sierra
Edif. Malco, Ave. Barbosa #427
Rio Piedras, PR 00928

Mailing Address:
Buzon 1246, Bo. Santa Rosa, Dorado, PR 00646

Union Status: NonUnion

SIC:1542

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/10/1986

Emphasis:

Case Closed: 10/07/1987


Related Activity
Type Activity Nr Safety Health
Referral 900590860 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 2 2
Initial Penalty $2,430 $0 $0 $0 $0 $2,430
Current Penalty $1,100 $0 $0 $0 $0 $1,100
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 6B0001 03/14/1986 03/15/1986 $810 $810 $0 04/07/1986 A - Amendment Citation has been deleted.
2. 01002 Serious 19260451 D07 03/14/1986 03/15/1986 $550 $810 $0 04/07/1986 L - State Settlement  
3. 01003 Serious 19260451 D10 03/14/1986 03/15/1986 $550 $810 $0 04/07/1986 L - State Settlement  
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close