Powered by GoogleTranslate

Inspection Detail

Inspection: 316948330 - North American Power Line Construction Services In

Inspection Information - Office: Eugene

 

Inspection Nr: 316948330
Report ID: 1054114
Date Opened: 08/10/2013

Site Address:
North American Power Line Construction Services In
4810 Willamette St
Eugene, OR 97405

Mailing Address:
Corporation Service Company 285 Liberty St Ne, Salem, OR 97301

Union Status: NonUnion

SIC:1623

NAICS: 237130/Power and Communication Line and Related Structures Construction


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/08/2014

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 05/30/2014


Related Activity
Type Activity Nr Safety Health
Accident 101201044
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $7,000 $0 $0 $0 $0 $7,000
Current Penalty $7,000 $0 $0 $0 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 703007301 02/04/2014 02/07/2014 $2,800 $2,800 $0 02/24/2014 W - Empr Withdrew  
2. 01002 Serious 19260502 D15 02/04/2014 02/07/2014 $1,400 $1,400 $0 02/24/2014 W - Empr Withdrew  
3. 01003 Serious 703007302 02/04/2014 02/07/2014 $2,800 $2,800 $0 02/24/2014 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 201205093
Event: 08/09/2013
Employee Fall from Aerial Lift, Later Dies

On August 9, 2013, an employee and a coworker were dispatched to make a repair on the top of a wooden light pole with communication equipment installed on the top of the pole. The workers using a Genie 65S aerial lift accessed their work area to make the repair. The repair was made and the employee and the coworker lowered the lift to the ground. The employee re-entered the aerial lift by himself to go back up to the work area to take photographs of their completed work. Another coworker working on the ground was conducting an electrical test on the repair that was completed. The employee raised the aerial lift into the air with the boom completely collapsed and the lift tipped over ejecting the employee onto the ground. The emergency medical services were called, and the employee was transported to the Peacehealth and Riverbend in Springfield, Oregon. It was determined that the employee had no brain activity and was transported to the Oregon Health Science University in Portland, Oregon for a second opinion. He was put on life support at the Peacehealth and was disconnected from it at the Oregon Health Science University. The employee passed away at 12:45 p.m. on August 23, 2013.

Keywords: CONCUSSION, AERIAL LIFT, MAINTENANCE, HOISTING MECHANISM, ELEC UTILITY WORK, FALL, WORK SURFACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316948330 Fatality Concussion Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close