Inspection Detail
Inspection: 316948330 - North American Power Line Construction Services In
Inspection Information - Office: Or Eugene
Site Address:
North American Power Line Construction Services In
4810 Willamette St
Eugene, OR 97405
Mailing Address:
Corporation Service Company 285 Liberty St Ne, Salem, OR 97301
Union Status: NonUnion
SIC:1623
NAICS: 237130/Power and Communication Line and Related Structures Construction
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/08/2014
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 05/30/2014
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 101201044 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | ||||
Current Violations | 3 | 3 | ||||
Initial Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
Current Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 703007301 | 02/04/2014 | 02/07/2014 | $2,800 | $2,800 | $0 | 02/24/2014 | W - Empr Withdrew | |
2. | 01002 | Serious | 19260502 D15 | 02/04/2014 | 02/07/2014 | $1,400 | $1,400 | $0 | 02/24/2014 | W - Empr Withdrew | |
3. | 01003 | Serious | 703007302 | 02/04/2014 | 02/07/2014 | $2,800 | $2,800 | $0 | 02/24/2014 | W - Empr Withdrew |
Investigation Summary
On August 9, 2013, an employee and a coworker were dispatched to make a repair on the top of a wooden light pole with communication equipment installed on the top of the pole. The workers using a Genie 65S aerial lift accessed their work area to make the repair. The repair was made and the employee and the coworker lowered the lift to the ground. The employee re-entered the aerial lift by himself to go back up to the work area to take photographs of their completed work. Another coworker working on the ground was conducting an electrical test on the repair that was completed. The employee raised the aerial lift into the air with the boom completely collapsed and the lift tipped over ejecting the employee onto the ground. The emergency medical services were called, and the employee was transported to the Peacehealth and Riverbend in Springfield, Oregon. It was determined that the employee had no brain activity and was transported to the Oregon Health Science University in Portland, Oregon for a second opinion. He was put on life support at the Peacehealth and was disconnected from it at the Oregon Health Science University. The employee passed away at 12:45 p.m. on August 23, 2013.
Keywords: CONCUSSION, AERIAL LIFT, MAINTENANCE, HOISTING MECHANISM, ELEC UTILITY WORK, FALL, WORK SURFACE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 316948330 | Fatality | Concussion | Occupation not reported |