Inspection Detail
Inspection: 312552300 - Tectron Tube
Inspection Information - Office: Appleton Area Office
Site Address:
Tectron Tube
650 Heritage Road
Depere, WI 54115
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3317
NAICS: 331210/Iron and Steel Pipe and Tube Manufacturing from Purchased Steel
Inspection Type: Planned
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/29/2009
Emphasis: L:Piv, L:Primetal, N:Amputate, S:Amputations, S:Powered Ind Vehicle
Case Closed: 08/26/2009
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $1,050 | $0 | $0 | $0 | $0 | $1,050 |
| Current Penalty | $525 | $0 | $0 | $0 | $0 | $525 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100212 A03 II | 07/10/2009 | 07/18/2009 | $525 | $525 | $0 | - | ||
| 2. | 02001 | Other | 19100022 A02 | 07/10/2009 | 07/14/2009 | $0 | $0 | $0 | - | ||
| 3. | 02002 | Serious | 19100219 E01 I | 07/10/2009 | 07/27/2009 | $0 | $525 | $0 | I - Informal Settlement |
Translate