Inspection Detail
Inspection: 308367713 - Parker-Hannifin Corporation, Tube Fittings Div
Inspection Information - Office: Cincinnati Area Office
Site Address:
Parker-Hannifin Corporation, Tube Fittings Div
725 N. Beech St.
Eaton, OH 45320
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3492
NAICS: 332912/Fluid Power Valve and Hose Fitting Manufacturing
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/06/2005
Emphasis:
Case Closed: 06/28/2006
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 1 | 4 | |||
| Current Violations | 3 | 1 | 4 | |||
| Initial Penalty | $17,000 | $0 | $0 | $1,000 | $0 | $18,000 |
| Current Penalty | $9,000 | $0 | $0 | $1,000 | $0 | $10,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100178 A04 | 01/20/2005 | 03/09/2005 | $3,000 | $7,000 | $0 | 02/04/2005 | R - Review Commission | |
| 2. | 01001B | Serious | 19100178 N06 | 01/20/2005 | 03/09/2005 | $0 | $0 | $0 | 02/04/2005 | R - Review Commission | Citation has been deleted. |
| 3. | 01002 | Serious | 19100178 L02 III | 01/20/2005 | 03/09/2005 | $3,000 | $5,000 | $0 | 02/04/2005 | R - Review Commission | |
| 4. | 01003 | Serious | 19100178 L03 | 01/20/2005 | 03/09/2005 | $3,000 | $5,000 | $0 | 02/04/2005 | R - Review Commission | |
| 5. | 02001 | Other | 19100178 P01 | 01/20/2005 | 02/01/2005 | $1,000 | $1,000 | $0 | 02/04/2005 | F - Formal Settlement |
Translate