Inspection Detail
Inspection: 304528631 - Quality Electroplating Corporation
Inspection Information - Office: Pr-E-Caguas 0257220
Site Address:
Quality Electroplating Corporation
Carr 1 Km 34.2 Villa Blanca Industrial Park
Caguas, PR 00725
Mailing Address:
Po Box 6570, Caguas, PR 00726
Union Status: NonUnion
SIC:3471
NAICS: 0
Inspection Type: Planned
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/09/2002
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 06/07/2002
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $2,450 | $0 | $0 | $175 | $0 | $2,625 |
| Current Penalty | $1,225 | $0 | $0 | $88 | $0 | $1,313 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100133 A03 | 04/30/2002 | 05/24/2002 | $613 | $1,225 | $0 | I - Informal Settlement | ||
| 2. | 01002A | Serious | 19100303 F | 04/30/2002 | 05/24/2002 | $612 | $1,225 | $0 | I - Informal Settlement | ||
| 3. | 01002B | Serious | 19100303 G01 | 04/30/2002 | 05/24/2002 | $0 | $0 | $0 | I - Informal Settlement | ||
| 4. | 02001 | Other | SPECRULE 1VI 11 | 04/30/2002 | 05/24/2002 | $88 | $175 | $0 | I - Informal Settlement |