Accident | 101250090 |
Investigation Summary
Employee #1 was installing a lateral antenna on the north leg of a communication tower and fell approximately 187 feet to the ground and was killed.
Keywords: COMMUNICATION TOWER, PPE, WALKING SURFACE, FALL, FALL PROTECTION, COMMUNICATION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 304341233 | Fatality | Other | Occupation not reported |