Inspection Detail
Inspection: 301277232 - Xantech Corp
Inspection Information - Office: High Hazard Unit - South
Site Address:
Xantech Corp
12950 Bradley Ave
Sylmar, CA 91342
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3643
NAICS: 335931/Current-Carrying Wiring Device Manufacturing
Inspection Type: Planned
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/04/2003
Planning Guide: Safety-Manufacturing
Emphasis: S:Targeted Compl & Consult
Case Closed: 04/24/2006
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 3 | 4 | |||
| Current Violations | 1 | 3 | 4 | |||
| Initial Penalty | $3,375 | $0 | $0 | $650 | $0 | $4,025 |
| Current Penalty | $3,375 | $0 | $0 | $650 | $0 | $4,025 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 25000008 A | 08/04/2003 | 09/03/2003 | $185 | $185 | $0 | - | ||
| 2. | 01002 | Other | 3277 F04 | 08/04/2003 | 09/03/2003 | $280 | $280 | $0 | - | ||
| 3. | 01003 | Other | 5194 F04 | 08/04/2003 | 09/03/2003 | $185 | $185 | $0 | - | ||
| 4. | 02001 | Serious | 3210 A | 08/04/2003 | 08/14/2003 | $3,375 | $3,375 | $0 | - |