Inspection Detail
Inspection: 17105081 - Custom Coils Inc
Inspection Information - Office: Inactive-Tyler
Site Address:
Custom Coils Inc
101 Anvil St
Jacksonville, TX 75766
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3498
NAICS: 0
Inspection Type: Planned
Scope: Complete
Advanced Notice:
Ownership:
Safety/Health: Safety
Close Conference: 08/13/1980
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/27/1980
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 2 | 5 | |||
| Current Violations | 3 | 2 | 5 | |||
| Initial Penalty | $400 | $0 | $0 | $0 | $0 | $400 |
| Current Penalty | $400 | $0 | $0 | $0 | $0 | $400 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100212 A03 II | 09/25/1980 | 09/06/1980 | $100 | $100 | $0 | - | ||
| 2. | 01002A | Serious | 19100217 C01 I | 09/03/1980 | 09/06/1980 | $100 | $100 | $0 | - | ||
| 3. | 01002B | Serious | 19100309 A 025042 | 09/03/1980 | 09/06/1980 | $0 | $0 | $0 | - | ||
| 4. | 01003 | Serious | 19100217 C02 IA | 09/25/1980 | 09/06/1980 | $200 | $200 | $0 | - | ||
| 5. | 02001 | Other | 19100104 B08 VIII | 08/18/1980 | 08/21/1980 | $0 | $0 | $0 | - | ||
| 6. | 02002A | Other | 19100184 E01 | 08/18/1980 | 08/22/1980 | $0 | $0 | $0 | - | ||
| 7. | 02002B | Other | 19100184 E07 II | 08/18/1980 | 08/22/1980 | $0 | $0 | $0 | - |
Translate