Powered by GoogleTranslate

Inspection Detail

Inspection: 121904783 - Burnham Foundry, Llc

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 121904783
Report ID: 0522500
Date Opened: 04/02/1998

Site Address:
Burnham Foundry, Llc
2345 Licking Road
Zanesville, OH 43701

Mailing Address:
P. O. Box 3148, Zanesville, OH 43702

Union Status: Union

SIC:3321

NAICS: 0 


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 04/02/1998

Emphasis: N:Silica

Case Closed: 09/17/1998


Related Activity
Type Activity Nr Safety Health
Complaint 202417770 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $1,875 $0 $0 $0 $0 $1,875
Current Penalty $1,125 $0 $0 $0 $0 $1,125
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100215 B09 04/07/1998 05/10/1998 $1,125 $1,875 $0 I - Informal Settlement  
2. 02001 Other 19100303 B02 04/07/1998 04/17/1998 $0 $0 $0 -  
3. 03001 Other 19101000 E 06/09/1998 07/12/1998 $0 $0 $0 -  
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close