Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1148336.015 - 130147 - Ron Haugen

Inspection Information - Office: Nc Department Of Labor - Charlotte

 

Inspection Nr: 1148336.015
Report ID: 0453730
Date Opened: 05/16/2016

Site Address:
130147 - Ron Haugen
Route 2, P.O. Box 32a
Wadesboro, NC 28170

Mailing Address:
2675 Cascade Creek Drive, Buford, GA 30519

Union Status: NonUnion

SIC:1799

NAICS: 238990/All Other Specialty Trade Contractors


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/16/2016

Emphasis:

Case Closed: 11/16/2016


Related Activity
Type Activity Nr Safety Health
Accident 1092927
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $9,800 $0 $0 $0 $0 $9,800
Current Penalty $6,400 $0 $0 $0 $0 $6,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19261408 A02 III B 09/22/2016 09/26/2016 $2,800 $2,800 $0 Z - Issued  
2. 01001B Serious 19261408 B03 09/22/2016 09/26/2016 $0 $0 $0 Z - Issued  
3. 01001C Serious 19261408 B04 II 09/22/2016 09/26/2016 $0 $0 $0 Z - Issued  
4. 01002 Serious 19261408 D01 09/22/2016 09/26/2016 $0 $2,800 $0 I - Informal Settlement  
5. 01003 Serious 19261412 F01 09/22/2016 09/26/2016 $1,800 $2,100 $0 I - Informal Settlement  
6. 01004 Serious 19261425 C02 09/22/2016 09/26/2016 $1,800 $2,100 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 85374.015
Event: 05/16/2016
Worker taking down cellular tower is electrocuted when boom

At approximately 1:10 p.m. on May 16, 2016, an employee was working for a firm of specialty trade contractors. He and some coworkers were working at a site where an old cellular tower had been dismantled on Sunday, May 15, 2016, the day before. The tower had already been removed and hauled away for scrap at the time of the incident. The workers were pulling up 2.4-meter by 4.9-meter (8-foot by 16-foot) wooden mats, similar to pallets. The mats had been used as a makeshift road to let a Mantex 30100 boom truck to access a fenced-in area. The workers had initially dragged the mats into place using a pickup truck. The workers elected to use the boom truck to remove the mats. There was an overhead power line some 5.5 to 6.1 meters (18 to 20 feet) above them. It was energized at 13.2 kV. The truck's boom was raised and near the overhead power line. Extending from the boom was a cable with a hook. The employee was holding the hook. He moved it a few meters or feet laterally. It came into contact with a phase conductor. The employee was electrocuted. A coworker was standing a few meters or feet away ready to place a sling on the hook. He was not injured.

Keywords: Antenna, Boom Truck, Construction, E GI IA (vehicle near lines), Electric Conductor, Electric Shock, Electrical, Electrocuted, Load Line, Overhead Power Line, Telecom Work

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1148336.015 38 M Fatality Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close