Inspection Detail
Inspection: 1148336.015 - 130147 - Ron Haugen
Inspection Information - Office: Nc Charlotte
Site Address:
130147 - Ron Haugen
Route 2, P.O. Box 32a
Wadesboro, NC 28170
Mailing Address:
2675 Cascade Creek Drive, Buford, GA 30519
Union Status: NonUnion
SIC:1799
NAICS: 238990/All Other Specialty Trade Contractors
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/16/2016
Emphasis:
Case Closed: 11/16/2016
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1092927 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 4 | ||||
Current Violations | 4 | 4 | ||||
Initial Penalty | $9,800 | $0 | $0 | $0 | $0 | $9,800 |
Current Penalty | $6,400 | $0 | $0 | $0 | $0 | $6,400 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19261408 A02 III B | 09/22/2016 | 09/26/2016 | $2,800 | $2,800 | $0 | Z - Issued | ||
2. | 01001B | Serious | 19261408 B03 | 09/22/2016 | 09/26/2016 | $0 | $0 | $0 | Z - Issued | ||
3. | 01001C | Serious | 19261408 B04 II | 09/22/2016 | 09/26/2016 | $0 | $0 | $0 | Z - Issued | ||
4. | 01002 | Serious | 19261408 D01 | 09/22/2016 | 09/26/2016 | $0 | $2,800 | $0 | I - Informal Settlement | ||
5. | 01003 | Serious | 19261412 F01 | 09/22/2016 | 09/26/2016 | $1,800 | $2,100 | $0 | I - Informal Settlement | ||
6. | 01004 | Serious | 19261425 C02 | 09/22/2016 | 09/26/2016 | $1,800 | $2,100 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 1:10 p.m. on May 16, 2016, an employee was working for a firm of specialty trade contractors. He and some coworkers were working at a site where an old cellular tower had been dismantled on Sunday, May 15, 2016, the day before. The tower had already been removed and hauled away for scrap at the time of the incident. The workers were pulling up 2.4-meter by 4.9-meter (8-foot by 16-foot) wooden mats, similar to pallets. The mats had been used as a makeshift road to let a Mantex 30100 boom truck to access a fenced-in area. The workers had initially dragged the mats into place using a pickup truck. The workers elected to use the boom truck to remove the mats. There was an overhead power line some 5.5 to 6.1 meters (18 to 20 feet) above them. It was energized at 13.2 kV. The truck's boom was raised and near the overhead power line. Extending from the boom was a cable with a hook. The employee was holding the hook. He moved it a few meters or feet laterally. It came into contact with a phase conductor. The employee was electrocuted. A coworker was standing a few meters or feet away ready to place a sling on the hook. He was not injured.
Keywords: Antenna, Boom Truck, Construction, E GI IA (vehicle near lines), Electric Conductor, Electric Shock, Electrical, Electrocuted, Load Line, Overhead Power Line, Telecom Work
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1148336.015 | 38 | M | Fatality | Occupation not reported |