Inspection Detail
Inspection: 1119754.015 - Air Liquide Large Industries Us, Lp Corpus Christi Steam Methane Reformer Plant
Inspection Information - Office: Corpus Christi Area Office
Site Address:
Air Liquide Large Industries Us, Lp Corpus Christi Steam Methane Reformer Plant
5880 Up River Rd
Corpus Christi, TX 78408
Mailing Address:
5880 Up River Rd, Corpus Christi, TX 78408
Union Status: NonUnion
SIC:
NAICS: 325120/Industrial Gas Manufacturing
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 06/21/2016
Emphasis:
Case Closed: 02/14/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 1055523 | Yes | Yes |
| Inspection | 1122899 | Yes | |
| Inspection | 1122873 | Yes | |
| Inspection | 1122854 | Yes | |
| Inspection | 1122701 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $7,000 | $70,000 | $0 | $0 | $0 | $77,000 |
| Current Penalty | $0 | $0 | $0 | $12,471 | $0 | $12,471 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100134 D01 III | 07/20/2016 | $0 | $7,000 | $0 | 08/08/2016 | F - Formal Settlement | Citation has been deleted. | |
| 2. | 02001 | Other | 19101200 H01 | 07/20/2016 | 08/10/2016 | $12,471 | $70,000 | $0 | 08/08/2016 | F - Formal Settlement |
Translate