Powered by GoogleTranslate

Inspection Detail

Inspection: 11144052 - Reddaway Mfg Co

Inspection Information - Office: Inactive-Newark

 

Inspection Nr: 11144052
Report ID: 0235100
Date Opened: 10/03/1979

Site Address:
Reddaway Mfg Co
32 Euclid Avenue
Newark, NJ 07105

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3292

NAICS: 0 


Inspection Type: Planned

Scope: Complete

Advanced Notice:

Ownership:  

Safety/Health: Safety

Close Conference: 10/05/1979

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/21/1979


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $600 $0 $0 $0 $0 $600
Current Penalty $600 $0 $0 $0 $0 $600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100145 C02 I 10/16/1979 10/05/1979 $250 $250 $0 -  
2. 01002 Serious 19100213 H04 10/16/1979 10/17/1979 $200 $200 $0 -  
3. 01003 Serious 19100219 F01 10/16/1979 11/13/1979 $150 $150 $0 -  
4. 02001 Other 19100212 B 10/16/1979 10/19/1979 $0 $0 $0 -  
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.