Inspection Detail
Inspection: 1108864.015 - Spates Fabricators Inc
Inspection Information - Office: San Bernardino District Office
Site Address:
Spates Fabricators Inc
85-435 Middleton St
Thermal, CA 92274
Mailing Address:
85435 Middleton St, Thermal, CA 92274
Union Status: NonUnion
SIC:
NAICS: 321214/Truss Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/15/2016
Emphasis:
Case Closed: 04/26/2017
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1031618 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 1 | 4 | |||
Current Violations | 2 | 2 | 4 | |||
Initial Penalty | $41,625 | $0 | $0 | $5,000 | $0 | $46,625 |
Current Penalty | $19,800 | $0 | $0 | $3,000 | $0 | $22,800 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 342(A) | 04/15/2016 | $3,000 | $5,000 | $0 | 05/02/2016 | C - Contested | ||
2. | 02001 | Serious | 43000001 A | 04/15/2016 | 04/27/2016 | $1,800 | $13,500 | $0 | 05/02/2016 | F - Formal Settlement | |
3. | 03001 | Serious | 43000001 C01 | 04/15/2016 | 04/27/2016 | $18,000 | $18,000 | $0 | 05/02/2016 | F - Formal Settlement | |
4. | 04001 | Other | 4301(B) | 04/15/2016 | 04/27/2016 | $0 | $10,125 | $0 | 05/02/2016 | F - Formal Settlement |