Powered by GoogleTranslate

Inspection Detail

Inspection: 102794765 - Bauer Aerospace Division Of Woodward

Inspection Information - Office: Hartford Area Office

 

Inspection Nr: 102794765
Report ID: 0112000
Date Opened: 03/18/1992

Site Address:
Bauer Aerospace Division Of Woodward
126 Hyde Road, Farmington Industrial Park
Farmington, CT 06032

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3812

NAICS: 0 


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/18/1992

Emphasis:

Case Closed: 09/04/1992


Related Activity
Type Activity Nr Safety Health
Complaint 74924028 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $3,750 $0 $0 $0 $0 $3,750
Current Penalty $2,000 $0 $0 $0 $0 $2,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100023 C01 06/29/1992 08/13/1992 $600 $1,125 $0 I - Informal Settlement  
2. 01002 Serious 19100253 B04 III 06/29/1992 07/23/1992 $600 $1,125 $0 I - Informal Settlement  
3. 01003A Serious 19100332 B01 06/29/1992 08/13/1992 $800 $1,500 $0 I - Informal Settlement  
4. 01003B Serious 19100333 B02 I 06/29/1992 08/13/1992 $0 $0 $0 -  
5. 02001 Other 19100022 D01 06/29/1992 08/13/1992 $0 $0 $0 -  
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close