Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 997601 - Employee burned by molten lead when fitting comes apart

Accident Summary Nr: 997601 -- Report ID: 0551800 -- Event Date: 11/25/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11497701011/27/199133410Rsr Quemetco Inc

Abstract: Employee #1 was turning a switch at a control panel to turn on a burner for kettle #1. Molten lead was being transferred from kettle #3 to kettle #7. A fitting on the pipe came apart, spraying molten metal in the direction of Employee #1. He was covered by the molten metal, mainly on his back side. He crawled to a safe location, where he and others removed his clothing. Medical help was called. Employee #1 sustained second- and third-degree burns over 46 percent of his body.

Keywords: BURN, EQUIPMENT FAILURE, MOLTEN METAL, PIPE, LEAD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 114977010 Hospitalized injury Burn/Scald(Heat) Supervisors, production occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.