Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 997379 - COAL PULVERIZER EXPLOSION AT POWER GENERATING STATION

Accident Summary Nr: 997379 -- Report ID: 0551800 -- Event Date: 03/17/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10393053303/19/198749110Public Service Indiana

Abstract: Three employees were following standard procedures to bring a coal pulverizer on line. When all dampers had been opened an explosion occurred in the pulverizer. Employees #1 and #2 were about 12 meters from the explosion, near an adjacent pulverizer, and received only burns to their faces. Employee #3 was on the mezzanine, above the explosion. He received burns to his face and forearm and suffered from mild smoke inhalation. He was hospitalized for his injuries. The cause of the explosion was not determined.

Keywords: BURN, COAL DUST, COAL, EXPLOSION, SMOKE, ELEC UTILITY WORK, COAL CRUSHER, SMOKE INHALATION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103930533 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 103930533 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 103930533 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.