Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 99314.015 - Employee amputates arm when caught in a conveyor nip point

Accident Summary Nr: 99314.015 -- Report ID: 0112000 -- Event Date: 09/22/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1266458.01509/26/2017423930Elg Utica Alloys (Hartford), Inc.

Abstract: At 8:45 p.m. on September 22, 2017, Employee #1 was standing at the start end of an inclined feed conveyor, placing scrap metal on the belt to be transported to a fragmentizer. A fragment of scrap metal came down the bottom of the conveyor and lodged in the in-running nip point of the belt and head pulley. The employee attempted to pull the material out, but his glove became caught in the nip point. Employee #1's lower left arm was pulled off. He was hospitalized for the injury.

Keywords: Caught In, Conveyor Belt, Glove, Jammed, Lockout/Tagout, Machine Guarding, Nip Point, Pulley

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1266458.015 52 M Hospitalized injury Machine feeders and offbearers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.