Accident Summary Nr: 99312.015 - Employee fractures leg when struck by swinging pipe

Accident Summary Nr: 99312.015 -- Report ID: 0316700 -- Event Date: 09/25/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1266437.01509/27/2017238220Commonwealth Fire Protection Company, Inc.

Abstract: At 10:30 a.m. on September 25, 2017, Employee #1 and Coworkers #1 and #2, employed by a fire protection services company, were working at a multiemployer construction site. They were installing underground piping for supplying sprinkler system water. Employee #1 and Coworker #1 were working in a trench that measured 4 feet wide, approximately 40 feet long, and less than 5 feet deep. The ductile iron pipe they were installing measured 19 feet long and 10 inches in diameter. Employee #1 and Coworker #1 stood at the ends of the pipe to help guide its centering in the trench. However, due to its weight, they could not lift the pipe to center it. Coworker #2, operating an excavator, lifted the pipe after attaching it to the excavator with a synthetic web sling. As the pipe rose, it began to swing laterally, and one end struck Employee #1's left leg, pinching the leg against an existing concrete storm sewer pipe that ran perpendicularly across the trench. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for crushing and blunt force trauma injuries, including a compound fracture to the leg that required multiple surgeries.

Keywords: Caught In, Construction, Crushing, Excavation, Fracture, Leg, Material Handling, Struck By, Trench, Water Pipe
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction New project or new addition   0 0

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1266437.015 59 M Hospitalized injury Pipelayer Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing underground plumbing conduit
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.