Accident Summary Nr: 98848.015 - Employee partially amputates two fingers in cycling press br

Accident Summary Nr: 98848.015 -- Report ID: 0521400 -- Event Date: 09/05/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1262392.01509/08/2017332114Millenia Products Group, Inc.

Abstract: At 11:00 a.m. on September 5, 2017, Employee #1, a machine operator trainee, was working in the roll form department alone, running a normal production of street light channels on the automatically actuating 100 ton Rousselle press brake, Model number 10K80, and Serial number 23751. The employee approached the machine at its front center to face the actively running operation of automatically cycling dies. Employee #1 then reached into the point-of-operation with his right hand to pick up a lubricant spray bottle that was placed there on the bolster plate, inches away from the closing dies. The employee picked up the spray bottle with his right hand and started spraying die pins about 5 inches away. The vertical clearance between the dies was between eight to ten inches. His left hand was empty and at some point, he leaned near the point-of-operation and the cycle activated, beginning to lower the top die while the employee's left hand was in the point-of-operation. Employee #1s left hand pinky and ring fingers were caught between the top and lower dies. The employee suffered an amputation to the pinky finger, losing the top two knuckles, and his ring fingers middle knuckle was amputated in the center. Employee #1 stopped the cycle by pressing/pulling the die sensor in the danger zone and went for help. Other coworkers responded to the scene while first responders were called. First aid measures were applied and first responders transported the employee by ambulance to a local emergency room. Employee #1 underwent outpatient hand surgery and was released the same day.

Keywords: Amputated, Amputation, Caught In, Die, Finger, Lockout/Tagout, Machine Guarding, Mechanical Power Press, Point Of Operation, Press Brake

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1262392.015 55 M Non Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close