Accident Summary Nr: 98448.015 - Worker operating saw has finger amputated in kick back

Accident Summary Nr: 98448.015 -- Report ID: 0111500 -- Event Date: 08/10/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1258102.01508/11/2017238140Culbertson Company Of New York

Abstract: At 9:30 a.m. on August 10, 2017, Employee #1 and Coworker #1, employed by a construction company, were working at a road job site. Employee #1 was operating a Bosch Circular Saw to rip a 2 by 4 piece of wood. Coworker #1 held the wood at the other end. The wood was partially set on the top edge of a concrete wall. As Employee #1 operated the saw, the saw kicked back and struck his left hand. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for the partial amputation of his left middle finger and a severe laceration to his left ring finger.

Keywords: Amputation, Circular Saw, Construction, Finger, Highway, Kick Back, Laceration, Masonry Wall, Repair, Wood Slab
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Highway, road, street Maintenance or repair   10

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1258102.015 42 M Hospitalized injury Carpenters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior masonry
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.