Accident Report Detail
Accident Summary Nr: 98314.015 - Employee falls from temporary work platform and is killed
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1256503.015 | 08/18/2017 | 238110 | Sbf Construction, Inc. |
Abstract: At 10:00 a.m. on August 18, 2017, an employee was stripping a temporary work platform over the elevator shaft on the 2nd floor. The temporary work platform collapsed while the employee was on it. The employee did not have fall protection and fell about 23 feet from 2nd floor to cellar level and died.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Multi-family dwelling | New project or new addition | 52 | X | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 1256503.015 | 22 | M | Fatality | Construction laborers | Distance of Fall: 23 feet Worker Height Above Ground/Floor: 0 feet Cause: Stripping and curing concrete Fatality Cause: |